DL380 G9

Cache Disks:

image-122-1024x568 S2D: VMFleet (HPE Gen9 Server)

Livemigration Test mit BIGVM (150GB RAM VM)

image-120 S2D: VMFleet (HPE Gen9 Server)
image-119 S2D: VMFleet (HPE Gen9 Server)

VMFleet Ergebnisse:

Storage = Nested 2 Way Mirror

2x 6TB

image-121-1024x193 S2D: VMFleet (HPE Gen9 Server)

10 VMs per NODE:

(20 VMs gesamt)

8k Bytes
8Threads
20Outstanding Ios
0%Write
100%Read
3500IOPS pro VM
image-126-1024x541 S2D: VMFleet (HPE Gen9 Server)
8k Bytes
8Threads
20Outstanding Ios
30%Write
70%Read
2000IOPS pro VM
image-127-1024x543 S2D: VMFleet (HPE Gen9 Server)
8k Bytes
8Threads
20Outstanding Ios
100%Write
0%Read
900IOPS pro VM
image-123-1024x548 S2D: VMFleet (HPE Gen9 Server)

_____________________________________________________________________________________________________________________________________________________________________________________________________________

15 VMs per NODE:

(30 VMs gesamt)

8k Bytes
8Threads
20Outstanding Ios
0%Write
100%Read
3000IOPS pro VM
image-124-1024x544 S2D: VMFleet (HPE Gen9 Server)
8k Bytes
8Threads
20Outstanding Ios
30%Write
70%Read
900IOPS pro VM
image-125-1024x546 S2D: VMFleet (HPE Gen9 Server)
8k Bytes
8Threads
20Outstanding Ios
100%Write
0%Read
400IOPS pro VM
image-128-1024x548 S2D: VMFleet (HPE Gen9 Server)

20 VMs per NODE:

(40 VMs gesamt)

8k Bytes
8Threads
20Outstanding Ios
0%Write
100%Read
1000IOPS pro VM
image-130-1024x546 S2D: VMFleet (HPE Gen9 Server)
8k Bytes
8Threads
20Outstanding Ios
30%Write
70%Read
400IOPS pro VM
image-129-1024x548 S2D: VMFleet (HPE Gen9 Server)
8k Bytes
8Threads
20Outstanding Ios
100%Write
0%Read
200IOPS pro VM
image-131-1024x543 S2D: VMFleet (HPE Gen9 Server)